Page 11 - Diferro-Katalog
P. 11

MP
                  TECHNICAL SPECIFICATIONS

                  Heating System         : Heat Transfer Oil
                  Max.Temperature        : 220°
                  Average Heating Time   : 60 - 80 min.
                  Average Cooling Time   : 150 min.
                  Power Supply           : 380 V – 3 Ph 50/60 Hz
                  Air Intake (bar)       : Min. 5 – Max. 8
                  Electrical System      : PLC Control
                  Felt Tension System    : Pneumatic
                  Felt Control System    : Automatic
                  Drive Speed Control    : AC Inverter
                  Paper Un-wind Re-wind  : Compressed Shaft
                  Weekly Programming     : Yes
                  Automatic Shut-Down    : Yes
                  Safety                 : 4 Emergency Buttons – Safety Wire
                  Software Language      : English (Optional)
                  Warranty               : 2 years Mechanical, 1 year Electrical  (User Fault Exempted)


                 OPTIONAL ACCESSORIES

                 1  Static Electricity Preventing Wire   5  Air-Shaft

                 2  Glass Table and Lightening           6  Chrome or Teflon Plated Drum
                 3  Ventilation Hood                     7  UPS Power Supply

                 4  Remote Access Module



























                                                                                          www.diferro.com.tr  11